Sl. No. |
Parameter |
Inland surface water sewers |
Public sewers |
Land of Irrigation |
Marine/coastal areas |
1. |
Colour and Odour |
All effort should be made to remove colour and unpleasant odour as far as practicable |
- |
25 |
All effort should be made to remove colour and unpleasant odour as for as practicable. |
2. |
Suspended Solids, mg/l, max |
100 |
600 |
200 |
For process wastewater
For Cooling water effluent 10% above total suspended matter of influent |
3. |
Particle size of suspended solids |
Shall pass 850 micron IS Sieve |
- |
- |
Floatable solids max. 3 mm
Settleable solids max. 856 micron |
5. |
Temperature |
Shall not exceed 5 0 C above the receiving water temperature |
|
|
Shall not exceed 5 0 C above the receiving water temperature |
7. |
Total residual chlorine mg/l max. |
1.0 |
- |
- |
1.0 |
8. |
Ammonical nitrogen (as N), mg/l max |
50 |
50 |
- |